Optical Sensors & Detector – UV Calibration
UV-REF-LED
High-Stability UV-REF-LED Reference Source for Calibration and Testing of UV Sensors and Radiometers
The UV-REF-LED is a precision ultraviolet reference light source engineered for accurate calibration and functional testing of UV sensors, photodiodes, and radiometers. Built around a temperature-stabilised UV LED emitter, it provides a highly reproducible and spectrally stable UV output, ideal for verifying sensor responsivity and linearity. The UV-REF-LED operates in UVC, UVB, or UVA wavelengths, depending on the model configuration, and is factory-calibrated to NIST/PTB standards for traceable irradiance values. Compact, rugged, and easy to operate, it enables rapid sensor verification in laboratories, production lines, or field environments without requiring complex optical benches. Designed for both research and industrial quality control, this device ensures consistent reference illumination for accurate UV sensor calibration, instrument verification, and performance validation.
Understanding UV-REF-LED
The UV-REF-LED functions as a portable, spectrally defined reference source for comparing or calibrating UV detectors. Its built-in driver electronics deliver constant current to the LED, ensuring stable output over time and temperature. Available in models covering 254 nm (UVC), 310 nm (UVB), and 365 nm (UVA), it allows precise wavelength-specific calibration. When used with photodiodes or radiometers, the UV-REF-LED provides a known irradiance level for verifying responsivity or instrument drift. Compact and energy-efficient, it is indispensable in calibration laboratories, UV system maintenance, and R&D applications requiring traceable UV output verification.
Technical Specifications
| Feature | Specification |
| Emission Wavelength (typical) |
254 nm / 310 nm / 365 nm (model-dependent)
|
| Spectral Bandwidth (FWHM) | 10 – 15 nm |
| Optical Output Power |
10 – 500 µW/cm² (customisable)
|
| Output Stability | < ±1 % over 8 hours |
| Calibration Reference |
Traceable to NIST / PTB
|
| Detector Compatibility |
SiC, GaP, or Si photodiodes, UV radiometers
|
| Power Supply |
5 V DC via USB or external adapter
|
| Operating Temperature | 0 … +50 °C |
| Lifetime |
> 10 000 hours continuous operation
|
| Housing Material |
Aluminium, anodised, UV-resistant
|
| Dimensions |
100 × 50 × 40 mm (approx.)
|
| Output Interface |
Optical port with collimating quartz window
|
Key Features and Advantages
Traceable UV Reference Output
Each UV-REF-LED unit is calibrated to NIST/PTB standards, providing a reliable irradiance reference for laboratory and field calibration of UV detectors.
Spectrally Stable Illumination
Temperature-stabilised electronics and constant-current drive maintain spectral stability within ±1 nm and power variation below 1 %, even during long test runs.
Multiple Wavelength Options
Available in UVC (254 nm) for sterilisation sensor calibration, UVB (310 nm) for photobiological testing, and UVA (365 nm) for industrial and curing sensor validation.
Compact and Portable Design
Lightweight and self-contained, the UV-REF-LED enables on-site sensor verification without requiring complex optical alignment or power conditioning.
Plug-and-Play Operation
Powered via standard USB or DC input, it can be directly interfaced with calibration benches, data loggers, or handheld radiometers.
Long-Term Stability
The LED module’s lifetime exceeds 10 000 hours, ensuring minimal recalibration frequency and dependable reference output over years of use.
Comprehensive Compatibility
Supports UV sensors, photodiodes, and radiometers from various manufacturers, simplifying cross-instrument verification and calibration processes.
By delivering stable, reproducible, and traceable UV output, the UV-REF-LED serves as the foundation for accurate detector calibration and performance assurance in industrial, medical, and research photonics applications.
Applications Across Industries
Calibration Laboratories
Used for verifying responsivity and linearity of UV photodiodes, radiometers, and dosimeters under controlled irradiance.
UV Disinfection and Sterilisation Systems
Enables periodic calibration of UVC sensors ensuring correct dosage monitoring in water and air treatment systems.
Medical and Phototherapy Equipment Testing
Provides known irradiance levels for validating UV-A/B phototherapy sensors and dosage control systems.
Industrial Curing and Printing
Calibrates UVA monitoring sensors used in adhesive curing, coating, and ink-drying processes.
Research and University Laboratories
Ideal for sensor calibration, optical material response studies, and photonic device development requiring precise UV reference data.
Quality Assurance and OEM Integration
Incorporates easily into automated production test setups for batch verification of UV detector modules.
The UV-REF-LED ensures reliable, repeatable, and traceable UV calibration across environmental, industrial, medical, and scientific sectors where accuracy and stability are paramount.
Why Choose United Spectrum Instruments?
-
Exclusive distributor of SGLUX UV-REF-LED reference sources in India
-
Local calibration traceable to NIST/PTB ensuring confidence in measurements
-
Expert technical consultation for UV sensor integration and verification
-
Competitive pricing and rapid delivery for labs and OEMs
-
Nationwide support including annual recalibration, documentation, and on-site training
FAQs
What is the purpose of the UV-REF-LED?
It provides a stable, traceable UV reference output for calibration and functional testing of UV detectors.
Which wavelengths are available?
Models are available in 254 nm (UVC), 310 nm (UVB), and 365 nm (UVA).
How is calibration traceability ensured?
Each unit is factory-calibrated to NIST/PTB standards with certificate documentation.
Can it be used in field conditions?
Yes, it’s portable and designed for both laboratory and field verification.
How does United Spectrum support customers in India?
Through local inventory, technical consultation, recalibration, and comprehensive after-sales service.
GET IN TOUCH WITH US
Have Any Questions ?
FAQs
What is the purpose of the UV-REF-LED?
It provides a stable, traceable UV reference output for calibration and functional testing of UV detectors.
Which wavelengths are available?
Models are available in 254 nm (UVC), 310 nm (UVB), and 365 nm (UVA).
How is calibration traceability ensured?
Each unit is factory-calibrated to NIST/PTB standards with certificate documentation.
Can it be used in field conditions?
Yes, it’s portable and designed for both laboratory and field verification.
How does United Spectrum support customers in India?
Through local inventory, technical consultation, recalibration, and comprehensive after-sales service.