Optical Sensors & Detector – UV Index Measurement
UV Index Photodiode SG01L-E5
SG01L-E5 – High-Sensitivity UV Index Photodiode for Accurate Solar Erythema and Environmental Radiation Measurement
The SG01L-E5 from SGLUX GmbH is a precision erythema-weighted UV photodiode engineered for accurate UV Index and solar radiation monitoring.
Built using Silicon Carbide (SiC) detector technology, the SG01L-E5 features excellent solar blindness (>10¹⁰) and a spectral response closely matching the CIE erythema action curve, allowing precise measurement of biologically effective UV radiation.
Its compact and stable design makes it ideal for integration into UV Index monitoring devices, environmental stations, and health-safety instrumentation.
With ultra-low dark current, high linearity, and a wide operating temperature range (−55 °C to +170 °C), it ensures dependable operation even under extreme climatic conditions.
The sensor is factory-calibrated and traceable to NIST/PTB standards, guaranteeing reliable and repeatable performance for professional meteorological and scientific applications.
Understanding UV Index Photodiode SG01L-E5
The SG01L-E5 UV Index Photodiode measures erythemally effective ultraviolet radiation within 221–358 nm, corresponding to the UV range responsible for skin erythema.
It operates as a pure UV photodiode, offering high stability, low noise, and linear response to incident UV intensity.
Its SiC-based solar-blind structure ensures complete insensitivity to visible and infrared light, providing precise erythema-weighted UV Index readings.
The compact TO-46 metal-can package enables seamless integration into environmental sensors, wearable UV monitors, and scientific systems requiring high reliability, traceable calibration, and long-term durability.
Technical Specifications
| Feature | Specification |
| Function |
Erythema-weighted UV Index photodiode
|
| Detector Material | Silicon Carbide (SiC) |
| Typical Responsivity at Peak Wavelength | 0.160 A/W |
| Wavelength of Max. Responsivity | 280 nm |
| Responsivity Range (S = 0.1 × Smax) | 221 … 358 nm |
| Visible Blindness (Smax / S>405 nm) | > 10¹⁰ |
| Active Area | 0.06 mm² |
| Dark Current (1 V reverse bias) | 0.2 fA |
| Capacitance | 15 pF |
| Short Circuit Current (10 mW/cm² at peak) | 960 nA |
| Temperature Coefficient | < 0.1 %/K |
| Operating Temperature | −55 … +170 °C |
| Storage Temperature | −55 … +170 °C |
| Soldering Temperature (3 s) | 260 °C |
| Maximum Reverse Voltage | 20 V |
| Calibration | NIST / PTB traceable |
| Housing | TO-46 metal can |
| Compatibility |
AMPCON / SGCD4 / VOLTCON / Digiboard systems
|
| Applications |
UV Index, solar erythema, environmental monitoring, photobiology research
|
Key Features and Advantages
Accurate Erythema-Weighted Response
The SG01L-E5 is engineered to replicate the CIE erythema action spectrum, ensuring biologically relevant UV Index measurement for skin exposure and solar studies.
Excellent Solar Blindness
Visible and infrared radiation are completely suppressed (>10¹⁰), ensuring the sensor measures only UV wavelengths of interest.
Advanced Silicon Carbide Detector Technology
SiC material provides superior thermal stability, radiation hardness, and longevity in outdoor solar environments.
High Sensitivity and Ultra-Low Noise
Dark current of just 0.2 fA delivers exceptional signal-to-noise ratio, ensuring accurate detection even under low UV levels.
Wide Temperature Stability
Operates reliably from −55 °C to +170 °C, making it suitable for continuous outdoor and research-grade applications.
Traceable Calibration and Repeatability
Each sensor is factory-calibrated to NIST/PTB standards, guaranteeing traceability and consistency across measurement systems.
Compact and Robust Design
The TO-46 metal-can package ensures mechanical stability, corrosion resistance, and long-term reliability.
Flexible System Integration
Easily interfaces with AMPCON, SGCD4, and VOLTCON amplifiers or directly into custom measurement electronics.
The SG01L-E5 UV Index Photodiode combines scientific-grade accuracy, environmental robustness, and traceable calibration, making it the preferred detector for UV Index, solar radiation, and erythema-effect measurement systems.
Applications Across Industries
Meteorological and Environmental Monitoring
Used in weather stations and UV Index networks for continuous solar radiation measurement and climatological research.
Public Health and Safety
Supports UV Index displays and alert systems for skin protection and public awareness.
Research and Education
Deployed in photobiology, atmospheric studies, and solar radiation experiments requiring calibrated UV sensors.
Smart City and IoT Integration
Integrates into UV monitoring nodes and IoT platforms for environmental data collection and safety analytics.
Agriculture and Material Testing
Used for monitoring UV exposure effects on crops, materials, and coatings in outdoor test fields.
Wearable and Portable UV Devices
Miniature design allows easy incorporation into personal UV Index monitors and handheld detectors.
The SG01L-E5 delivers consistent, traceable, and scientifically accurate erythema-weighted UV Index measurements — empowering industries, research institutions, and public safety networks to monitor and manage solar exposure effectively.
Why Choose United Spectrum Instruments?
-
Official distributor of SGLUX UV Index Photodiodes in India
-
Expertise in UV sensing, calibration, and environmental instrumentation
-
Local calibration traceability to NIST/PTB standards
-
Competitive pricing for research institutes, OEMs, and environmental agencies
-
Pan-India support for integration, calibration, and after-sales service
FAQs
What does the SG01L-E5 measure?
It measures erythemally weighted UV radiation corresponding to the human skin sensitivity curve (CIE action spectrum).
Is it sensitive to visible or IR light?
No – it has solar blindness >10¹⁰, detecting only UV wavelengths.
What is the typical application?
UV Index monitoring, solar radiation analysis, and public health or environmental safety systems.
Is the sensor calibrated?
Yes – every unit is factory-calibrated and traceable to NIST/PTB standards.
How does United Spectrum assist Indian customers?
Through integration support, calibration services, and nationwide technical assistance for all UV photodiode applications.
GET IN TOUCH WITH US
Have Any Questions ?
FAQs
What does the SG01L-E5 measure?
It measures erythemally weighted UV radiation corresponding to the human skin sensitivity curve (CIE action spectrum).
Is it sensitive to visible or IR light?
No – it has solar blindness >10¹⁰, detecting only UV wavelengths.
What is the typical application?
UV Index monitoring, solar radiation analysis, and public health or environmental safety systems.
Is the sensor calibrated?
Yes – every unit is factory-calibrated and traceable to NIST/PTB standards.
How does United Spectrum assist Indian customers?
Through integration support, calibration services, and nationwide technical assistance for all UV photodiode applications.