Optical Sensors & Detector – UV Photodetectors
UV Index Photodetector (Erythema) – TOCON_E_OEM
TOCON_E_OEM – Precision UV Index and Erythema Photodetector for Accurate Solar UV Monitoring and Dosimetry
The TOCON_E_OEM from SGLUX GmbH is a compact, factory-calibrated UV Index photodetector specifically designed for accurate erythema-weighted UV measurement in solar monitoring, environmental research, and safety applications. It integrates a UV-sensitive photodiode with an internal low-noise transimpedance amplifier to deliver a linear 0–5 V DC output proportional to incident erythemally weighted irradiance. Its spectral response precisely matches the CIE erythema action curve (ISO 17166 / CIE S007-1998), enabling direct correlation with human skin UV exposure and global UV Index standards. The TOCON_E_OEM offers traceable NIST/PTB calibration, long-term stability, and excellent cosine response for outdoor and laboratory measurements. Built within a rugged anodised aluminium TOCON housing, it’s ideal for UV Index monitoring stations, solar simulators, environmental chambers, and OEM sensor integrations requiring accurate, maintenance-free, and reliable erythemal UV evaluation.
Understanding UV Index Photodetector (Erythema) - TOCON_E_OEM
The TOCON_E_OEM is an erythema-weighted UV detector optimised for precise UV Index measurement. Its internal amplifier provides a stable 0–5 V analog signal, directly readable by data loggers, PLCs, and SGLUX SENSOR MONITOR 5.0 systems. With spectral matching to the CIE erythema response, it ensures reliable simulation of biological skin response to UV exposure. The detector’s factory calibration (traceable to NIST/PTB) guarantees accurate, repeatable readings across various lighting and environmental conditions. Compact, linear, and temperature-stable, the TOCON_E_OEM is the professional choice for solar UV measurement, environmental monitoring networks, and safety compliance instrumentation.
Technical Specifications
| Feature | Specification |
|---|---|
| Function | Erythema-weighted UV Index photodetector with integrated amplifier |
| Detector Type | Silicon carbide (SiC) or UV photodiode with internal transimpedance amplifier |
| Spectral Range | 250 – 400 nm (CIE erythema weighted) |
| Peak Sensitivity | Approx. 297 nm (matches erythemal action spectrum) |
| Output Signal | 0 – 5 V DC (linear with erythema-weighted irradiance) |
| Calibration | Factory-calibrated, traceable to NIST / PTB standards |
| Accuracy | ±5 % of reading |
| Response Time | < 1 s |
| Operating Voltage | 5 – 24 V DC |
| Operating Temperature | −20 … +85 °C |
| Housing Material | Anodised aluminium TOCON enclosure |
| Optical Window | UV-grade quartz |
| Connector | BNC / M8 / custom cable output |
| Compatibility | SENSOR MONITOR 5.0 / VOLTCON / SGCD4 |
| Applications | UV Index monitoring, solar radiation measurement, environmental and health safety instrumentation |
Key Features and Advantages
Accurate Erythema-Weighted UV Response
The TOCON_E_OEM precisely replicates the CIE erythema action spectrum, ensuring accurate correlation with human skin sensitivity to UV exposure. It’s engineered for reliable UV Index determination under natural sunlight or artificial UV sources.
Integrated Amplifier with Direct Voltage Output
Equipped with a built-in low-noise transimpedance amplifier, it produces a clean, linear 0–5 V analog output, enabling direct connection to measurement devices without the need for external amplification.
Traceable Calibration and Long-Term Stability
Each TOCON_E_OEM sensor is factory-calibrated to NIST/PTB standards, providing certified accuracy, long-term reproducibility, and minimal drift under continuous outdoor exposure.
Infrared and Visible Light Rejection
Thanks to its erythema-matched spectral filter and UV-selective photodiode, the detector effectively eliminates visible and infrared light interference, ensuring spectral purity.
Fast and Reliable Response
With a response time of less than one second, the sensor enables real-time UV Index tracking, crucial for safety systems and automated UV exposure control.
Rugged Design for Industrial and Outdoor Use
The anodised aluminium housing with UV-grade quartz window protects the sensor from humidity, dust, and UV degradation, making it suitable for harsh outdoor environments.
Seamless System Integration
Fully compatible with SENSOR MONITOR 5.0, VOLTCON, and SGCD4, the TOCON_E_OEM easily integrates into monitoring networks and OEM instrumentation for environmental and industrial use.
Applications Across Industries
Solar UV Index Monitoring
Deployed in meteorological and environmental stations, the TOCON_E_OEM continuously measures erythema-weighted UV irradiance to calculate real-time UV Index values for public health and climatology studies.
Occupational and Public Safety Systems
Integrated into UV safety systems, it monitors human UV exposure in outdoor workplaces, ensuring compliance with ICNIRP and ISO UV exposure limits.
Environmental and Atmospheric Research
Used in scientific observatories, it supports long-term solar UV radiation studies, climate modelling, and ozone layer impact assessments.
Solar Simulator and Lamp Characterisation
Provides calibrated reference readings for UV lamp testing, solar simulators, and photobiological research, ensuring precise dose and irradiance control.
OEM and Industrial Integration
Compact and stable, it’s easily embedded into OEM measurement systems, UV Index displays, or portable UV dosimeters for industrial and consumer applications.
Health and Dermatological Studies
In dermatology and phototherapy research, the sensor enables accurate simulation and quantification of erythema-effective radiation, supporting medical device calibration and treatment validation.
Why Choose United Spectrum Instruments?
-
Exclusive distributor of SGLUX TOCON_E_OEM in India
-
Expertise in UV Index and erythema-weighted measurement systems
-
Local calibration services traceable to NIST / PTB
-
Custom integration for OEM, industrial, and research projects
-
Pan-India technical support with on-site installation and calibration services
United Spectrum Instruments delivers certified UV measurement technology with unmatched support and domain expertise, ensuring your UV monitoring and safety systems meet the highest international standards for accuracy and reliability.
FAQs
What is the detection range of the TOCON_E_OEM?
It covers 250–400 nm, matching the CIE erythema action spectrum, ideal for UV Index measurement.
Is it affected by visible or infrared light?
No, it features built-in spectral filtering that rejects visible and IR radiation completely.
Does it need external amplification?
No, it includes an integrated low-noise amplifier providing a 0–5 V analog output.
Is it calibrated?
Yes, it’s factory-calibrated and traceable to NIST/PTB standards for certified accuracy.
What support does United Spectrum offer in India?
Local calibration, integration, and technical services for OEM, industrial, and research customers across India.
GET IN TOUCH WITH US
Have Any Questions ?
FAQs
What is the detection range of the TOCON_E_OEM?
It covers 250–400 nm, matching the CIE erythema action spectrum, ideal for UV Index measurement.
Is it affected by visible or infrared light?
No, it features built-in spectral filtering that rejects visible and IR radiation completely.
Does it need external amplification?
No, it includes an integrated low-noise amplifier providing a 0–5 V analog output.
Is it calibrated?
Yes, it’s factory-calibrated and traceable to NIST/PTB standards for certified accuracy.
What support does United Spectrum offer in India?