Optical Sensors & Detector – UV Calibration
UV Calibration, Certified Water Sensors
Certified UV Calibration Water Sensors for Precise Monitoring and Validation of UV Disinfection and Purification Systems
The Certified UV Calibration Water Sensors are precision photometric devices specifically designed for accurate UV irradiance measurement and performance validation in water disinfection, purification, and treatment systems. These sensors continuously monitor UV intensity inside reactors to ensure proper sterilisation performance, helping maintain compliance with international standards such as DVGW, OVGW, USEPA, and ISO 9001. Each unit undergoes traceable calibration to NIST or PTB standards, ensuring accuracy and long-term stability. Built from high-grade stainless steel with quartz or sapphire optical windows, these sensors resist corrosion and high pressure, making them ideal for industrial, municipal, and laboratory water systems. Available in UVC (200–280 nm), UVB, and UVA configurations, they deliver reliable, real-time feedback for UV lamp output verification and regulatory reporting. Compact, durable, and factory-certified, the sensors form the backbone of safe, compliant, and efficient UV-based water disinfection operations.
Understanding UV Calibration, Certified Water Sensors
Certified UV Calibration Water Sensors are designed for inline and submersible UV intensity measurement within water treatment systems. They ensure the correct UV dose for microbial disinfection by monitoring lamp performance over time. Each sensor contains a UVC-sensitive SiC or GaP photodiode, protected by a quartz or sapphire window for high UV transmission and chemical resistance. These sensors are individually calibrated against certified UV standards (NIST/PTB), guaranteeing consistent, traceable accuracy. Compact, watertight, and temperature-compensated, they deliver precise data under varying flow and pressure conditions. Ideal for compliance-driven applications, they provide essential verification for regulated water purification systems and UV sterilisation units.
Technical Specifications
| Feature | Specification |
| Measurement Parameter |
UV Irradiance (mW/cm²) / UV Dose (mJ/cm²)
|
| Spectral Range |
UVC (200–280 nm) / UVB (280–315 nm) / UVA (315–400 nm)
|
| Detector Type |
SiC or GaP Photodiode (calibrated)
|
| Calibration Standard | NIST / PTB traceable |
| Sensitivity Range |
0.01 µW/cm² – 100 mW/cm²
|
| Accuracy | ±3% (typical) |
| Response Time | < 100 ms |
| Operating Pressure |
Up to 10 bar (model-dependent)
|
| Optical Window |
UV-grade Quartz / Sapphire
|
| Housing Material |
Stainless Steel (AISI 316L or Titanium optional)
|
| Operating Temperature | 0 … +70 °C |
| Connector Type |
Waterproof M12 / Cable Gland (custom)
|
| Output Signal |
0–10 V / 4–20 mA / RS-485 Modbus (optional)
|
| Certification Options |
DVGW / OVGW / USEPA / ISO 9001 compliant
|
| Maintenance Interval |
Annual calibration recommended
|
Key Features and Advantages
Certified and Traceable Calibration
Each UV water sensor is factory-calibrated against NIST or PTB standards, ensuring traceability, repeatability, and confidence in performance verification.
Purpose-Built for Water Disinfection Systems
Engineered for use inside UV reactors and flow chambers, these sensors provide accurate measurement of UV irradiance and dose to confirm proper disinfection levels.
High Durability and Chemical Resistance
Constructed with stainless steel or titanium housings and quartz/sapphire optics, they resist corrosion, scaling, and biofouling in water treatment environments.
Real-Time Monitoring and Data Integration
With analogue (4–20 mA, 0–10 V) and digital (RS-485/Modbus) outputs, these sensors easily integrate into PLCs, SCADA, or UV monitoring systems.
Temperature and Pressure Resilience
Fully sealed for submersion, the sensors operate under pressures up to 10 bar and maintain stability over a wide temperature range.
Compliance with Global Standards
Certified for use in systems compliant with DVGW (Germany), OVGW (Austria), USEPA (USA), and ISO 9001, ensuring acceptance across regulatory frameworks.
Low Maintenance, Long Lifespan
The solid-state photodiode design ensures no degradation under continuous UV exposure, reducing maintenance frequency and operational downtime.
By combining traceable calibration, rugged construction, and process connectivity, these sensors ensure safe and verifiable operation of UV water purification systems worldwide.
Applications Across Industries
Municipal Water Treatment
Monitors UV intensity in large-scale water purification systems ensuring microbial inactivation and compliance with public safety standards.
Industrial Water Purification
Used in food, beverage, pharmaceutical, and semiconductor industries for maintaining sterile process water quality.
Laboratory and R&D Testing
Supports calibration and validation of laboratory UV reactors and pilot-scale disinfection systems.
Wastewater and Effluent Monitoring
Ensures effective UV exposure in tertiary treatment systems and reuse water facilities.
Aquaculture and Aquarium Systems
Monitors UV lamp performance for biosecurity and pathogen control in marine and freshwater environments.
Portable UV Disinfection Systems
Ideal for compact or mobile UV purification devices used in medical, field, or emergency water sanitisation setups.
With precision calibration and durable construction, these UV calibration water sensors ensure regulatory compliance, operational reliability, and high disinfection efficiency across diverse water treatment applications.
Why Choose United Spectrum Instruments?
-
Exclusive distributor of certified UV sensors for water treatment in India
-
Local calibration and certification support for DVGW, OVGW, and ISO standards
-
Expert consultation for system integration and sensor selection
-
Competitive pricing for OEM, industrial, and municipal clients
-
Nationwide after-sales service, maintenance, and recalibration assistance
FAQs
What makes these sensors “certified”?
Each sensor is calibrated to NIST/PTB standards and certified for DVGW or USEPA compliance.
Can they be used inside pressurised UV reactors?
Yes, models rated up to 10 bar are suitable for inline or submersible use.
What spectral range do they cover?
Models are available for UVC, UVB, and UVA measurement depending on application.
How often should they be calibrated?
Annual recalibration is recommended to maintain certification accuracy.
How does United Spectrum support Indian customers?
Through local stock availability, technical integration support, calibration partnerships, and nationwide service coverage.
GET IN TOUCH WITH US
Have Any Questions ?
FAQs
What makes these sensors “certified”?
Each sensor is calibrated to NIST/PTB standards and certified for DVGW or USEPA compliance.
Can they be used inside pressurised UV reactors?
Yes, models rated up to 10 bar are suitable for inline or submersible use.
What spectral range do they cover?
Models are available for UVC, UVB, and UVA measurement depending on application.
How often should they be calibrated?
Annual recalibration is recommended to maintain certification accuracy.
How does United Spectrum support Indian customers?
Through local stock availability, technical integration support, calibration partnerships, and nationwide service coverage.