Optical Sensors & Detector – UV Calibration
UV-Arc Validation Set
Precision UV-Arc Validation Set for Accurate Verification and Calibration of UV Radiometers and Sensors
The UV-Arc Validation Set is a high-precision reference system designed to verify and calibrate UV radiometers, photodiodes, and measurement heads under controlled optical conditions. It utilises a stabilised UV arc lamp with known spectral output and an integrated reference detector calibrated to NIST/PTB standards, providing traceable irradiance values across UVA, UVB, and UVC regions. The system enables laboratory-grade validation of sensor linearity, spectral accuracy, and repeatability. Featuring adjustable output intensity, interchangeable optical filters, and a stable power regulation circuit, the UV-Arc Validation Set simulates real-world UV exposure while maintaining measurement consistency. It is ideal for R&D laboratories, calibration centres, and industrial QA departments requiring certified UV verification standards. Compact, robust, and simple to operate, it ensures accurate performance testing for UV detectors, disinfection sensors, and radiometric instruments.
Understanding UV-Arc Validation Set
The UV-Arc Validation Set provides a traceable UV light reference using a precisely regulated arc discharge lamp that emits a continuous spectrum across 200–400 nm. By positioning the test sensor at a defined distance from the source, users can verify irradiance readings against a certified reference detector. The included control unit stabilises lamp intensity and monitors output in real time. Designed for repeatable calibration and instrument verification, it allows comparative testing of multiple UV sensors under identical conditions. The system’s portability and reproducibility make it indispensable for field validation, sensor production testing, and radiometer recalibration.
Technical Specifications
| Feature | Specification |
| Light Source |
Mercury or Xenon Arc Lamp (stabilised)
|
| Spectral Range |
200 – 400 nm (UVC, UVB, UVA)
|
| Output Irradiance |
0.1 – 10 mW/cm² (adjustable)
|
| Spectral Bandwidth | Continuous emission |
| Reference Detector |
NIST/PTB-calibrated SiC or GaP photodiode
|
| Calibration Traceability |
NIST / PTB standards
|
| Stability (8-hour operation) | < ±1 % |
| Distance to Detector |
100 mm (standard; adjustable)
|
| Power Supply | 230 V AC / 50 Hz |
| Cooling System |
Forced-air or liquid cooling (model dependent)
|
| Warm-up Time | < 15 minutes |
| Operating Temperature |
20 … 25 °C (laboratory)
|
| Control Interface |
Digital display with real-time irradiance readout
|
| Optional Filters |
UVA, UVB, UVC bandpass / neutral density
|
Key Features and Advantages
Traceable Calibration and Verification
Each UV-Arc Validation Set is calibrated against NIST or PTB standards, ensuring international traceability for UV irradiance measurements.
Stable Continuous UV Spectrum
The mercury or xenon arc lamp provides broadband UV radiation ideal for validating both narrowband and wide-spectrum sensors.
Adjustable Output Intensity
Allows fine control of irradiance levels to simulate real-world UV exposure or to match specific test requirements.
Reference Detector Integration
A built-in calibrated photodiode continuously monitors lamp output, maintaining stable irradiance throughout the validation process.
Versatile Optical Configuration
Supports interchangeable optical filters for band-specific calibration (UVA, UVB, UVC) and adjustable working distances.
High Measurement Repeatability
Temperature-controlled housing and stabilised power supply ensure consistent optical output with less than 1% variation.
Comprehensive Software and Data Logging
Optional PC software enables data acquisition, comparison, and calibration certificate generation for traceability documentation.
By combining broadband UV emission, precise irradiance control, and reference calibration, the UV-Arc Validation Set provides a complete solution for UV sensor validation, radiometer testing, and optical system benchmarking.
Applications Across Industries
Calibration Laboratories
Serves as a primary UV reference for verifying and recalibrating photodiodes, radiometers, and UV sensors.
Water and Air Disinfection Systems
Validates UVC sensor performance to ensure accurate dosage monitoring and compliance with disinfection safety standards.
Industrial Manufacturing QA
Used in production lines for periodic verification of UV curing and coating process sensors.
Research and Metrology Institutes
Provides spectral reference measurements for scientific studies in photochemistry, photobiology, and optical materials testing.
Medical and Phototherapy Device Testing
Assures precise UV intensity calibration in therapeutic equipment and diagnostic instruments.
Semiconductor and Surface Processing
Supports calibration of UV exposure sensors used in wafer lithography and photoresist systems.
By offering traceable reference light, excellent stability, and repeatable measurement geometry, the UV-Arc Validation Set guarantees accurate, compliant, and reliable UV calibration for industrial, medical, and scientific applications.
Why Choose United Spectrum Instruments?
-
Exclusive distributor of SGLUX UV-Arc Validation Systems in India
-
Calibration traceable to NIST/PTB with local verification support
-
Expertise in radiometric testing and UV calibration integration
-
Competitive pricing for research, QA, and OEM customers
-
Nationwide service, on-site training, and annual recalibration support
FAQs
What is the purpose of the UV-Arc Validation Set?
It provides a traceable UV reference for validating radiometers and sensors.
Which UV ranges are supported?
UVC, UVB, and UVA from 200 to 400 nm.
What kind of lamp is used?
High-stability mercury or xenon arc lamp with regulated power control.
How accurate is the irradiance stability?
Better than ±1 % over an 8-hour operation period.
How does United Spectrum support Indian customers?
Through local calibration, expert guidance, fast delivery, and nationwide service.
GET IN TOUCH WITH US
Have Any Questions ?
FAQs
What is the purpose of the UV-Arc Validation Set?
It provides a traceable UV reference for validating radiometers and sensors.
Which UV ranges are supported?
UVC, UVB, and UVA from 200 to 400 nm.
What kind of lamp is used?
High-stability mercury or xenon arc lamp with regulated power control.
How accurate is the irradiance stability?
Better than ±1 % over an 8-hour operation period.
How does United Spectrum support Indian customers?
Through local calibration, expert guidance, fast delivery, and nationwide service.