Optical Sensors & Detector – Transducer for Photodiodes
RADIKON-Simple
RADIKON-Simple UV Radiometer for Reliable Real-Time Measurement of UVA, UVB and UVC Irradiance in Industrial Applications
The RADIKON-Simple is a compact, easy-to-operate UV radiometer designed for accurate irradiance and exposure monitoring in both laboratory and industrial environments.
Developed by SGLUX, it utilises precision SiC or GaP photodiodes to measure UVC, UVB or UVA radiation with exceptional linearity and spectral selectivity.
Its robust electronics and calibrated detector ensure traceable measurements in W/m² or mJ/cm², suitable for UV curing, disinfection, and research validation tasks.
Featuring a clear LCD display, user-selectable ranges, and a durable metal housing, the RADIKON-Simple delivers real-time readings without external software or PC control.
Pre-calibrated to NIST/PTB standards, it provides dependable, maintenance-free UV intensity monitoring for production lines, environmental testing, and academic laboratories where simplicity, stability, and accuracy are paramount.
Understanding RADIKON-Simple
The RADIKON-Simple operates as a stand-alone digital UV radiometer, converting the photodiode current directly into an optical irradiance value.
Users can instantly view UV intensity and cumulative dose on its display, eliminating the need for complex setup or calibration adjustments.
Each instrument is factory-calibrated for a specific spectral band (UVC, UVB or UVA) and temperature-compensated for field reliability.
Powered by batteries or external DC input, the device is ideal for routine process checks, quality verification, or equipment calibration.
With traceable accuracy and intuitive operation, the RADIKON-Simple offers a cost-effective yet professional solution for everyday UV monitoring.
Technical Specifications
| Feature | Specification |
| Measurement Quantity |
UV Irradiance (W/m²) and Dose (mJ/cm²)
|
| Spectral Range Options |
UVC (200–280 nm), UVB (280–315 nm), UVA (315–400 nm)
|
| Detector Type |
SiC / GaP photodiode (SGLUX detector head)
|
| Calibration Traceability | NIST / PTB certified |
| Measurement Range |
0.01 µW/cm² – 20 W/cm²
|
| Accuracy | ±5 % of reading |
| Display |
Backlit LCD, 4-digit resolution
|
| Power Supply |
Internal Li-ion battery / 5 V DC adapter
|
| Battery Life |
Up to 12 hours continuous use
|
| Response Time | < 100 ms |
| Data Output |
Optional USB for data logging
|
| Operating Temperature | 0 … +60 °C |
| Housing |
Anodised aluminium, IP54 rated
|
| Dimensions | 110 × 70 × 35 mm |
| Weight | Approx. 300 g |
| Accessories |
Calibrated UV detector head + protective case
|
Key Features and Advantages
User-Friendly Operation
Designed for straightforward use, the RADIKON-Simple requires no software or calibration knowledge — switch on and read UV intensity instantly.
Traceable Measurement Accuracy
Factory calibration to NIST/PTB standards guarantees globally comparable and repeatable results.
Selectable Spectral Versions
Available in UVC, UVB, and UVA versions, each tailored for specific industrial or scientific applications.
Fast Response and Stability
High-speed electronics and temperature-compensated detection ensure stable, real-time measurement accuracy.
Portable and Rugged Design
Compact, battery-powered, and housed in a robust metal enclosure for on-site or field measurements.
Versatile Applications
Suitable for UV curing control, lamp testing, sterilisation verification, photobiological research, and environmental monitoring.
Optional Data Logging
USB connectivity allows optional recording and analysis through UVPlot or standard CSV software.
Maintenance-Free Calibration
Each unit retains its calibration stability for years, requiring only periodic verification.
By combining precision optics, digital simplicity, and industrial durability, the RADIKON-Simple delivers dependable UV measurement for everyday professional use.
Applications Across Industries
UV Disinfection and Sterilisation
Measures UVC lamp output in air, surface, and water disinfection systems to verify performance and safety compliance.
Industrial UV Curing
Monitors lamp intensity and exposure time in printing, coating, and adhesive curing processes for quality control.
Environmental and Solar Monitoring
Used for UVA and UVB measurement in climate and UV Index stations.
Calibration and Research Laboratories
Acts as a traceable reference instrument for radiometer and lamp calibration.
Medical and Phototherapy Applications
Ensures accurate UV dose delivery in therapeutic and dermatological devices.
Educational and Process Validation
Provides simple, reliable UV measurement for universities and industrial audits.
With its plug-and-measure simplicity, traceable accuracy, and rugged design, the RADIKON-Simple is the trusted tool for scientists and engineers needing quick, accurate UV validation on the spot.
Why Choose United Spectrum Instruments?
-
Official distributor of SGLUX RADIKON Series Radiometers in India
-
Local calibration support traceable to NIST/PTB standards
-
Expert consultation for UV curing, sterilisation, and environmental applications
-
Competitive pricing for research institutes, OEMs, and industry users
-
Nationwide technical service and after-sales assistance
FAQs
What does the RADIKON-Simple measure?
It measures UV irradiance (W/m²) and dose (mJ/cm²) in real time.
Is it available for different UV ranges?
Yes – UVA, UVB, and UVC versions are available with dedicated calibrations.
Does it require a PC to operate?
No, it is a stand-alone device with its own LCD display; USB logging is optional.
How accurate is it?
±5 % of reading, with traceable factory calibration.
How does United Spectrum support Indian customers?
Through local distribution, calibration verification, and nationwide technical support.
GET IN TOUCH WITH US
Have Any Questions ?
FAQs
What does the RADIKON-Simple measure?
It measures UV irradiance (W/m²) and dose (mJ/cm²) in real time.
Is it available for different UV ranges?
Yes – UVA, UVB, and UVC versions are available with dedicated calibrations.
Does it require a PC to operate?
No, it is a stand-alone device with its own LCD display; USB logging is optional.
How accurate is it?
±5 % of reading, with traceable factory calibration.
How does United Spectrum support Indian customers?