Ind Dust Fume Extractor – Laser Fume Extractor
AD Oracle iQ W3

In high-performance laser manufacturing, operator safety and air purity are non-negotiable. The AD Oracle iQ W3, designed and engineered by Donaldson BOFA, sets a new benchmark in precision fume extraction for laser welding and cutting applications. W3 certified under European regulations for welding fumes, this system is compact, intelligent, and powerful—providing industry-leading filtration and connectivity.
Officially distributed in India by United Spectrum Instruments, the AD Oracle iQ W3 delivers unmatched performance for laser facilities that demand clean air, digital system diagnostics, and reliable compliance with safety standards.
Understanding AD Oracle iQ W3
The AD Oracle iQ W3 is engineered for demanding welding environments where harmful metal fumes and gases are generated. Certified to W3 standards, it guarantees safe fume extraction when working with stainless steel, galvanised steel, and other metals. Its dual-blower system provides stable airflow, while the iQ platform delivers advanced diagnostics and filter life data. With extended filter capacity, quiet operation, and energy-efficient performance, the AD Oracle iQ W3 is the trusted choice for industries requiring safe, compliant, and reliable fume extraction.
Technical Specifications
| Metric | ||
| Dimensions (HxWxD) | 975 x 450 x 525 mm | |
| Weight | 71 kg | |
| Airflow / Pressure | 370 m³/hr / 96 mbar | |
| Electrical data | 100-230 V 50/60 Hz Full load current: 1.2 amps | |
| Noise level (at typical operating speed) | < 70 dBA | |
| Cabinet construction | Brushed stainless steel |
Key Features and Advantages
W3 Certification
Complies with EN ISO 15012-1:2013 W3 standard for safe fume extraction in welding processes, including stainless steel.
iQ Operating Platform
Provides live system feedback, predictive maintenance alerts, and filter monitoring, maximising uptime and efficiency.
Dual-Blower System
Delivers powerful and stable airflow, ensuring consistent performance in demanding welding environments.
Advanced Multi-Stage Filtration
Equipped with HEPA and activated carbon filters to remove particulates, gases, and harmful fumes with high efficiency.
Durable & Reliable Build
Designed for continuous, industrial-grade operation in harsh environments.
Energy Efficiency
Optimised blowers and long-life filters reduce energy usage and operating costs.
Advantages:
-
-
-
W3 certification ensures compliance for stainless steel and high-risk welding applications
-
Protects operators and equipment from hazardous welding fumes and gases
-
Real-time monitoring minimises downtime and reduces maintenance costs
-
Delivers high-capacity airflow in compact, space-efficient design
-
Ensures compliance with global workplace health and safety standards
-
Quiet operation enhances working comfort in industrial facilities
-
Extended filter life improves sustainability and reduces running costs
-
Trusted solution for industries requiring certified, continuous welding fume extraction
-
-
Applications Across Industries
Metal Welding & Fabrication
Certified for stainless steel and galvanised metal welding, ensuring effective removal of harmful fumes at the source.
Automotive & EV Manufacturing
Protects operators during welding of chassis, battery housings, and other metal components in high-volume production.
Aerospace & Defence
Used for welding and fabrication of critical aerospace parts, maintaining compliance with strict air quality standards.
Shipbuilding & Heavy Engineering
Removes high volumes of hazardous fumes generated during continuous heavy-duty welding operations.
Electronics & Precision Metalworking
Controls welding fumes in fabrication of enclosures, mounts, and delicate precision components.
Medical Device Manufacturing
Ensures safe conditions when welding stainless steel tools, implants, and equipment frames.
Research & Training Facilities
Supports technical institutes and training centres by ensuring fume-free environments during welding practice and demonstrations.
The AD Oracle iQ W3 combines W3 certification, intelligent diagnostics, and robust airflow capacity, making it an essential solution for industries requiring compliance, safety, and reliability in welding environments.
Why Choose United Spectrum Instruments?
United Spectrum Instruments is the authorised distributor of Donaldson BOFA AD Oracle iQ W3 systems in India, offering expert guidance and support.
-
Genuine W3-certified units with full manufacturer warranty
-
Expert installation, commissioning, and service across India
-
Application-specific advice for automotive, aerospace, medical, and metal fabrication sectors
-
Competitive pricing with reliable after-sales support
FAQs
What does W3 certification mean?
W3 certification ensures that the extraction system is compliant with EN ISO 15012-1 for removing welding fumes, including those generated from stainless steel and high-alloy metals. This allows safe recirculation of filtered air back into the workspace in some regulatory regions.
How does the iQ system benefit my operation?
The iQ operating system delivers real-time system status, filter condition, and airflow data, allowing proactive maintenance, improved uptime, and easier integration with your plant’s monitoring network.
Can the Oracle iQ W3 be used with robotic laser systems?
Absolutely. The system is ideal for both manual and robotic setups, especially in high-precision or high-volume laser welding and cutting operations. It offers stable airflow even in automated workcells.
What maintenance is required?
Regular inspection of the pre-filter and scheduled replacement of the HEPA and gas filters based on system alerts. The iQ diagnostics simplify maintenance planning by displaying the exact filter condition in real time.
Is the system loud during operation?
No. The AD Oracle iQ W3 is acoustically optimised and runs below 60 dBA, making it one of the quietest fume extraction systems in its class—perfect for labs and production environments.
GET IN TOUCH WITH US
Have Any Questions ?
FAQs
What does W3 certification mean?
W3 certification ensures that the extraction system is compliant with EN ISO 15012-1 for removing welding fumes, including those generated from stainless steel and high-alloy metals. This allows safe recirculation of filtered air back into the workspace in some regulatory regions.
How does the iQ system benefit my operation?
The iQ operating system delivers real-time system status, filter condition, and airflow data, allowing proactive maintenance, improved uptime, and easier integration with your plant’s monitoring network.
Can the Oracle iQ W3 be used with robotic laser systems?
Absolutely. The system is ideal for both manual and robotic setups, especially in high-precision or high-volume laser welding and cutting operations. It offers stable airflow even in automated workcells.
What maintenance is required?
Regular inspection of the pre-filter and scheduled replacement of the HEPA and gas filters based on system alerts. The iQ diagnostics simplify maintenance planning by displaying the exact filter condition in real time.
Is the system loud during operation?
No. The AD Oracle iQ W3 is acoustically optimised and runs below 60 dBA, making it one of the quietest fume extraction systems in its class—perfect for labs and production environments.